TMAX-SSR-HPayment:
L/C, T/T, Western Union, Credit Cards, PaypalShipping port:
Xiamen PortLead Time:
5 DaysCertificate:
CE, IOS, ROHS, SGS, UL CertificateWarranty:
Two years limited warranty with lifetime technical supportHigh Temperature Krebs Viscometer Machine with Liquid-Crystal Display
The high temperature viscometer adopts coaxial center structure, uses the small quantity sample adapter, each measurement needs the sample quantity to be very small, the temperature control is quick and accurate. Full range, all stop linearity through the PC interface, with different viscosity of standard samples for measurement correction, to ensure that the instrument has high accuracy and repeatability. Wide range of measurements suitable for testing of different materials.
Main features:
1. horizontal bubble front, sitting adjustment level can be very convenient.
2. have timing measurement function. Most of the samples we measured were typical non-Newtonian liquids with viscosity other than temperature and shear
In addition to the rate, it is also related to the length of the measurement. To make the measured data comparable, the measured time
It must be consistent.
3. the display accuracy of the measured data is two decimal places.
4. measurement data is displayed directly on the LCD screen without secondary calculation;
5. use small sample adapters, the amount of samples required for testing is very small, usually only 15-20 ml;
6. temperature range: room temperature plus 10℃-250℃(optional 300 heating furnace);
7. viscometer with RS232 interface can be directly connected to the micro printer.
Detailed technical parameters:
model
|
RV-SSR-H
(NDJ-1C) |
HA-SSR-H |
HB-SSR-H
(NDJ-1F) |
display |
liquid-crystal display |
||
Speed
(r/min) |
0.5/1/2/2.5/4/5/10/15/20/25/30/40/50/60/70/80/90/100 共18种转速 |
||
rotor
|
21,27,28,29 (standard configuration) |
||
measuring range
(mPa.s) |
50 - 2M
21rotor:50-100K
27rotor:250-500K
28rotor:500-1M
29rotor:1K-2M |
100 – 4M
21rotor:100-200K
27rotor:500-1M
28rotor:1K-2M
29rotor:2K-4M |
400 – 16M
21rotor:400-8M
27rotor:2K-4M
28rotor:4K-8M
29rotor:8K-16M |
K = 1,000; M=1,000,000 |
|||
Test error |
±3% (Newtonian liquid) |
||
repetitive error |
±1.5%(Newtonian liquid) |
||
Temperature control range |
Room temperature plus 10℃-250℃ (300℃ optional) |
||
Temperature control accuracy |
0.1℃ |
||
Print interface |
have |
Our company also has a number of stepless speed control touch screen high temperature viscometer (right image), the maximum range of 80 million, optional data software, showing shear rate and viscosity rheological curve
Standard configuration:
main engine |
1 |
rotor |
21,27,28,29 |
Sample containers |
2 |
manual of operation |
11 |
temperature regulating device |
1 |
furnace |
1 |
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damage part for you for free.
Previous :
Lab High Temperature Brookfield Viscometer with PC InterfaceNext :
Lab Brockfield Viscometer Machine with 5-Inch Color Touch ScreenCategories
© Copyright: 2024 Xiamen Tmax Battery Equipments Limited All Rights Reserved.
IPv6 network supported